Applications/Uses
After connecting the power supply and equipment, turn on the power switch. Press the SET button to start temperature setting. When the display flashes, use the Up and Down arrow buttons to set the desired temperature. Press SET again to confirm the setting and return to the main display. When the heating indicator light is on, the heating process has started. Once the temperature reaches the preset value, the heater automatically stops heating and the heating indicator light turns off. If the temperature drops below the preset value, the heater automatically resumes heating. The display shows the real-time temperature, and the system continuously cycles to maintain the preset temperature.
- The unit must be properly grounded. Keep it away from moisture, flammable materials, hazardous substances, and combustible gases.
- Never operate the heater without an air supply. Do not use the unit to heat flammable, explosive, or corrosive gases or liquids.
- Warning: Before operation, turn on the air supply first, then switch on the heater. After operation, turn off the heater power first, then shut off the air supply.
Specifications
| Model |
AHDD-500W |
| Air Flow Rate | 400 L/min |
| Air Inlet/Outlet | 3/8" |
| Power | 220V/50HZ |
| Control Temperature | 0-100゚C |
| Net Weight | 5 kg |